Operating load case

An operating load case describes a specific condition of a piping system with defined temperatures, pressures, contents and, where applicable, further loads.

Also
Operating case · Operating condition · Thermal case
Also known as
  • Operating case
  • Operating condition
  • Thermal case
01

An operating load case is a specific condition

An operating load case describes the piping as it actually is in a particular operating condition: with a temperature for each section, a pressure, a state of filling and the movements of the connected equipment. Unlike the design load case it is not an upper bound but a snapshot.

A stress analysis normally contains several of them. A single case “everything hot” describes only the simplest plant completely.

02

Which conditions belong to it

Which operating load cases have to be considered follows from the mode of operation – and needs to be clarified with process engineering and the owner.

  • Normal operation at the usual temperatures and pressures.
  • Start-up and shutdown, when parts of the line heat up or cool down at different times.
  • Redundant trains: one pump running, the second cold on standby.
  • Bypasses that carry flow only part of the time.
  • Steam-out, flushing or regeneration at temperatures different from operation.
03

What operating load cases are needed for

The operating load cases yield the quantities that determine the everyday life of the line: displacements at every support, loads on supports and structure, connection loads on equipment in the hot condition, and the sizing of spring hangers with hot and cold load.

For the thermal expansion stress check it is not a single condition that counts but the difference between two. What governs is the largest stress range occurring between any two conditions – the cold installed condition included.

04

Why the forgotten case is often the worst

Two parallel pump trains, one hot and one cold, load the common header differently from two hot trains: the cold train holds where the hot one wants to push. Such mixed conditions frequently produce the highest connection loads but appear in no design table.

The reference temperature is part of the load case too. Thermal expansion is calculated against the temperature at which the line was installed; for cryogenic lines or installation in winter this is not a minor detail.

What Entracon offers here is on the matching page.

See what we offer
Overview

Example: operating load cases of two parallel pump trains

Load case Train A Train B
Installed condition cold cold
Normal operation A operating temperature cold, on standby
Normal operation B cold, on standby operating temperature
Changeover operating temperature operating temperature
Steam-out steam-out temperature steam-out temperature
Frequently asked questions

Frequently asked questions about Operating load case

What is the difference between an operating load case and a design load case?

The design load case is the most severe condition, used to size wall thickness and rating. The operating load case is an actual condition; displacements, support loads and connection loads follow from it.

How many operating load cases does a stress analysis need?

As many as the plant has distinguishable conditions. For a single line between two items of equipment one may suffice; branched systems with redundant machinery often need several.

Which temperature is used for thermal expansion?

The temperature of the respective operating load case, relative to the installation temperature. Some project specifications require the design temperature instead; this is permissible but gives higher forces than occur in operation.