Picking up, moving and emptying a 200-litre drum in zone 1

A full 200-litre drum weighs 200 to 250 kilograms depending on the medium. In a zone 1 area, however, the lifting aid is not the first question. The first question is: what does the explosion protection document say – and which ignition sources may exist at this place at all?

Container
drum 200 l, canister 30 l
Weight
200 to 250 kg
Zone
zone 1 (gas), partly zone 21
Movement
lift, travel, tilt
Drive
pneumatic
Environment
solvent-laden, conductive floor
01 — The task

The zone is in the document. The equipment follows from it.

The drum arrives on a pallet, has to be picked up, moved to the filling station, raised and tilted for emptying. The area is classified as zone 1, the floor is conductive, the medium contains solvents. A forklift cannot reach into the tight space, and an overhead crane would be too crude for positioning at the bung. What is needed is a unit that guides the load instead of letting it swing – and that may be operated in this zone.

02 — The solution

How we solve it

The selection does not start in the catalogue

We read the explosion protection document first. From it follow the zone, the equipment category and the temperature class – and only from those the permissible design. There is no such thing as a unit “with ATEX”; there are units for a given category in a given zone. Reverse that order and you buy a version that may not be operated, and you find out at acceptance.

Pneumatics instead of electrics – and what that costs

In zone 1 we work with a purely pneumatic drive: lifting axis or articulated arm on compressed air, control through pneumatic valves, no electronics in the hazardous area. That is proven and robust but has consequences for the design. Compressed air is more expensive than electricity, speed depends on flow rate, and routing needs space. We calculate the demand in advance so the finished station does not hang on an undersized network.

Earthing, coating, inspection

Every conductive part is included in the equipotential bonding; the leakage resistance is measured and documented. For solvent-resistant cleaning we choose the coating accordingly – a standard powder coating does not last long. And because an Ex unit remains a work device, we plan the recurring inspection from the start: here it is not a nuisance but the proof that the protective measure still works.

03 — What changes

At the workstation afterwards

  • The drum is guided rather than swung – including when positioning at the bung.
  • The operator no longer stands under the load or in the tilting path.
  • The design is assigned to the zone and backed by a declaration of conformity.
  • Earthing and leakage resistance are measured and documented – ready for acceptance.
  • The recurring inspection is scheduled before the unit goes into service.
Frequently asked questions

Frequently asked questions

Is a zone 2 unit also good for zone 1?

No. The categories build on each other: a category 3 unit (zone 2) may not be operated in zone 1, while the reverse is fine. Anyone looking to save should therefore first check whether the specific place really is zone 1 – sometimes a more precise zoning shows the station at the edge lies in zone 2.

What about dust – zone 21?

Dust is a separate case with its own categories and a temperature assessment for dust layers. We then design for zone 21, pay attention to smooth surfaces with little build-up and agree the cleaning regime. Combinations of gas and dust zones occur and are no problem if they are described from the outset.

Can we retrofit an existing unit?

Rarely worthwhile. In legal terms a retrofitted unit is a substantial modification: conformity has to be reassessed, documented and declared – by whoever carries out the conversion. All in all the factory Ex version is almost always cheaper than retrofitting plus reassessment.